B727 Emergency Procedures

  1. ENGINE FIRE OR SEVERE DAMAGE OR SEPARATION
    Essential Power Selector: Operating Generator FE

  2. ENGINE FAILURE AND SHUTDOWN
    Essential Power Selector: OPERATING GEN FE
  3. ELECTRICAL SMOKE/FUMES OR FIRE
    • Oxygen Masks and Regulators (if req'd): ON ALL
    • Smoke Goggles (if req'd): ON ALL
    • Crew Communications: Establish ALL
    • If smoke/fumes source can be located,(this is never the case) Electrical/ Power (affected equip): REMOVE FE
    • If smoke/fumes source cannot be located, (this is always the case)
    • Tank 2 Boost Pump Switches: LEFT FORWARD AND RIGHT AFT ON FE
    • Fuel Crossfeed Selectors: OPEN FE
    • Generator Breaker Switches: TRIP FE
  4. LOSS OF ALL GENERATORS
    • Essential Power Selector: STANDBY FE
    • Battery: CHECK ON FE
    • Field Switches: CLOSE FE
    • If Field Off light(s) remain illuminate:
    • Battery Switch: OFF, IMMEDIATELY ON FE
    • Field Switches:CLOSE
    • If all Field Off Lights remain illuminated, land at the nearest suitable airport.
    • Essential Power Selector: OPERATING GENERATOR FE
  5. ONE OR TWO GENERATORS INOPERATIVE
    Essential Power Selector: OPERATING GENERATOR FE
  6. CABIN ALTITUDE WARNING OR RAPID DEPRESSURIZATION
    • Oxygen Masks and Regulators: ON 100% ALL
    • Crew Communications: ESTABLISH ALL
    • Engine Bleed Air Switches: CHECK TWO OPEN FE
    • Pack Switches: CHECK TWO ON FE