exam 5

  1. Question 1



    Guidelines or standards for the radiology department have been set by the: Joint Committee on EducationThe Joint Commission on Healthcare OrganizationsNational Council on Radiation Protection hospital administrator


    Question 2



    Positions and lines of authority are shown on a(n): flow chart NCRP chartorganizational chart TJC chart


    Question 3



    The primary concern of a radiology department is: meeting inspection standardsproviding quality patient care procuring the most modern equipment maintaining adequate personnel


    Question 4



    Infection control in radiology departments is: confined to special procedures optional in the diagnostic arearequired for all hospital areascritical for students to learn


    Question 5



    The safe operation of radiologic equipment is the concern of the: committee on in-service educationcommittee on radiation safety committee on infection control committee on hospital standards


    Question 6



    The safety of the working environment for radiology that is mandated by law is the responsibility of: American Radiologic Sciences Organization The Joint CommissionOccupational Safety and Health Administration National Council on Radiation Protection and Measurements


    Question 7



    When purchasing radiology equipment, the administration must consider the following, except the: economic factorssimplicity of operation needs of the department maintenance requirements


    Question 8



    Verifying the competence of the radiography staff is the responsibility of the: hospital administrator radiologistradiology administrator chief CT technologist


    Question 9



    Radiologic equipment must meet the standards of the: American Radiological Sciences Organization National Council of Radon ProtectionThe Joint CommissionBureau of Radiological Health Standards


    Question 10



    To make the purchase of new equipment economically sound, the following conditions must exist, except:the type of equipment is irrelevantmaintenance and repair service is available there must be space the patient load is sufficient to support the investment


    Question 11



    The cost of retakes in the radiology department includes the cost of: equipmentall of the above film and chemistry (in a nondigital setting) technical staff


    Question 12



    In a general hospital which examination is most frequently done: fluoroscopic studieschest abdomen studies kidney


    Question 13



    An electrolytic recovery unit recovers silver from the: film dryer unit Developer transport systemFixer


    Question 14



    The system of prospective payment for Medicare is based on:diagnosis related groups doctor reimbursement guide doctor recommended guide diagnostic radiography growth


    Question 15



    The most effective way technologists can reduce cost for radiologic tests is to: reduce the number of films for the test use high speed screensavoid retakes use CR or DR


    Question 16



    Chest radiographs in the typical hospital comprise approximately: 40% 20% 10%30%


    Question 17



    To produce a quality radiograph, all of the following patient characteristics must be considered, except: heightrace weighttemperament


    Question 18



    Quality assurance is the responsibility of the:all of the above hospital administrator staff technologists chief radiologist


    Question 19



    In evaluating the department for quality, you would check: ethnic background of employees vacation days of employeesskills of medical and professional employees length of service of employees


    Question 20



    Techniques used to assess quality care given to patients are:interviewing patientsall of the above observation of technologists at work interviewing technologists


    Question 21



    Quality assurance involves the following, except: equipment and suppliescultural diversity of patients technical and medical personnel discarded radiographs


    Question 22



    The only individual in a radiology department who can legally make a diagnosis is the: chief technologistradiologist radiology administrator quality assurance administrator


    Question 23



    In graphing the acceptance limits of a radiographic test, a: broad low curve indicates excellent qualitybroad low curve indicates a short range quality high narrow curve indicates medium standardshigh narrow curve indicates high standards


    Question 24



    The roentgen unit is a measure of the:amount of silver atoms on film number of ions created in tissuenumber of ions created in air amount of fluorescence from screens


    Question 25



    Total filtration in the x-ray tube must be the equivalent of at least:1.0 mm aluminum 1.5 mm aluminum 0.5 mm aluminum2.5 mm aluminum


    Question 26



    The rad is defined as a measure of:radiation absorbed dose radiation affective dose relative altered dose radiation applied dose


    Question 27



    The stage of life most sensitive to radiation is: elderly all may be equally affected adultfetus


    Question 28



    High radiation dose to the gonads may cause: cataractssomatic damage bremsstrahlunggenetic damage


    Question 29



    The length of the exposure cord of a mobile x-ray unit should be at least: 2 feet8 feet 4 feet6 feet


    Question 30



    The law of Bergonié and Tribondeau implies that radiosensitivity is greatest in:cells that are rapidly dividing cells that are highly differentiated cells that make up the nervous system cells that divide slowly over time
Author
gbrooks2
ID
121573
Card Set
exam 5
Description
exam 5
Updated