EXW Tent Camp Fundamentals

Card Set Information

Author:
MajinSektor
ID:
137507
Filename:
EXW Tent Camp Fundamentals
Updated:
2012-02-24 19:57:23
Tags:
EXW
Folders:

Description:
Study these Cards to get EXW Qualified
Show Answers:

Home > Flashcards > Print Preview

The flashcards below were created by user MajinSektor on FreezingBlue Flashcards. What would you like to do?


  1. Tent Camp Fundamentals




    ABFC
    Advanced Base Funtional Components
  2. Tent Camp Fundamentals




    Advanced Base Funtional Components
    A method of planning, procuring, assembling and shipping material and personnel to satisfy contingency operations
  3. Tent Camp Fundamentals




    P-437
    ABFC CNO approved TOA's
  4. Tent Camp Fundamentals




    P-437 Volume's
    • Volume 1: Reproducible Drawings
    • Volume 2: Technical Data
  5. Tent Camp Fundamentals
    Tent Placement:




    Galley to Scullery
    100 ft
  6. Tent Camp Fundamentals
    Tent Placement:




    Galley to Trash
    100 ft
  7. Tent Camp Fundamentals
    Tent Placement:




    Galley to Shower
    100 yrds
  8. Tent Camp Fundamentals
    Tent Placement:




    Galley to Toilets
    100 yrds
  9. Tent Camp Fundamentals
    Tent Placement:




    Fuel to Everything
    50 ft
  10. Tent Camp Fundamentals
    Tent Placement:




    Toilets to Berthing
    50 ft
  11. Tent Camp Fundamentals
    Tent Placement:




    Toilets to Water Supply
    100 yrds
  12. Tent Camp Fundamentals
    Tent Placement:




    Trash to Water Supply
    100 yrds
  13. Tent Camp Fundamentals




    Trash Pit
    • 4ft x 4ft x 4ft
    • Fill to 1ft from top
    • 100 persons per day
  14. Tent Camp Fundamentals




    4 Hole Burn Out
    • 25 people per tiolet
    • 3 to 1 diesel to gas mixture
  15. Tent Camp Fundamentals




    Generators
    80% load (5-volt loss in 200m)




    • Main- 100kw, 60kw, 30kw
    • Back up- 5kw, for COC/ACOC/Medical/Galley
  16. Tent Camp Fundamentals




    ROWPU
    Reverse Osmosis Water Purification Unit




    • 600gal per hour freash water
    • 400gal per hour salt water
    • Set up to 75ft from water supply
    • Set up units up stream from camp
  17. Tent Camp Fundamentals




    Hose Color Codes
    • Raw Water- Black
    • Waste Water- Red
    • Potable Water- Blue
    • Brine Water- Purple
    • Filter Water- Yellow
  18. Tent Camp Fundamentals
    Distances:




    Latrines must be ____ from Messing Facilities
    300ft
  19. Tent Camp Fundamentals
    Distances:




    Latrines must be ____ away from potable water and ____ from the gray water
    50ft, 300ft
  20. Tent Camp Fundamentals




    Leach Field
    • Herringbone Pattern
    • 4"-6" perforated pipe
    • Branches are 5'-10' apart
    • Used to dispose gray water into the ground
  21. Tent Camp Fundamentals




    Four Classes of Work
    • 1. Safety
    • 2. Functional
    • 3. Preventative
    • 4. Appearance
  22. Tent Camp Fundamentals




    Three types of Inspection
    • 1.Controlled
    • 2. Annual
    • 3. Operator
  23. Tent Camp Fundamentals




    Chlorination
    5ppm (parts per million), Not less than 2ppm after 30min
  24. Tent Camp Fundamentals




    Super Chlorination
    100ppm, Not less than 50ppm, after 4 hours
  25. Tent Camp Fundamentals




    Classes of Fires
    • A-Wood: CO2/Water
    • B-Liquid: CO2/Drychem
    • C-Electrical: De-energize/CO2/PKP
    • D-Metals: Jettison/Bury
  26. Tent Camp Fundamentals




    Water Supply
    • 22 gal/day w/Shower & Laundry
    • 15 gal/day w/Shower
  27. Tent Camp Fundamentals




    Three Types of work in Camp Maintenance
    • 1. Emergency- less thann 16 man hours
    • 2. Specific- more than 16 man hours
    • 3. Standing Job ¬†Order- Repetitive in nature, over 40 man hours

What would you like to do?

Home > Flashcards > Print Preview