  1. L/R DUCT OV TEMP
    • pack compressor discharge >225c
    • distribution duct >82c
  2. L/R RECIRC
    fan speed dropped to 80%
  3. L/R BLEED AIR LEAK
    hot air in bleed detector loop >205c
  4. L/R BLEED FAULT
    • stuck valve
    • pres downsteam of valve >43.5psi
    • temp upstream of valve >288c
    • ac pack compressor discharge >225c
    • distribution duct >82c
    • switch off
    • fire handle pulled
  5. L/R BLD CLOSED
    valve closed
  6. XVALVE OPEN
    valve is open
  7. L/R HP HIGH
    stuck valve