320 Lights and Switches

Home > Preview

The flashcards below were created by user obinvb on FreezingBlue Flashcards.


  1. Oxygen Panel
    Mask Man on in Auto
    Mask doors signalled to open with cabin alt > 14,000
  2. Oxygen Panel
    Mask Man on pushed
    masks doors are manually signalled to open
  3. RCDR Panel
    CVR GND CTL pb AUTO, when is CVR on
    • 1.  On ground, for 5 minutes after electrical power applied
    • 2.  ON ground, after engine start
    • 3. Continuously in flight, whether engines operating or not
  4. RCDR Panel
    CVR erase pb
    pressed for 2 seconds, erases tape if on ground and parking brake set
  5. Fire Panel
    ENG 1 (2) FIRE pb
    • Red when Fire warning is active.
    • Pushed and released
    • 1. Silences warning horn
    • 2. Arms squib
    • 3. Closes HYD fire valve
    • 4. Closes LP fuel valve
    • 5. Deactivates IDG
    • 6. Secures Power to FADEC
    • 7. Closes Pack Flow Control Valve
    • 8. Closes engine Bleed Valve 
  6. Fire Panel
    Eng 1(2) Test pb
    • 1. CRC
    • 2. Squib lights on
    • 3. DISCH lights on
    • 4. Light in Fire Light
    • 5. Master Warn Light on
    • 6. Eng FIRE 1 (2) Ecam
    • 7. Fire light on ENG panel red
  7. Fire Panel
    APU FIRE pb
    • Red when fire warning activated
    • Pushed and Released
    • 1. Shuts down APU
    • 2. Silences Horn
    • 3. Arms Squib
    • 4. Closes LP Fuel valve
    • 5. Shuts off APU fuel pump
    • 6. Deactivates APU Gen
    • 7. Closes APU bleed valve and x-bleed valve
  8. GPWS Panel
    LDG FLAP 3 pb
    • ON: "Too Low Flaps" inhibited when Flaps 3 selected.
    • ECAM landing memo shows Flaps.....3  isntead of full
  9. EMER ELEC PWR Panel
    GEN 1 LINE pb
    Smoke
    Illuminates amber with smoke detected in velntilation duct
  10. EMER ELEC PWR Panel
    GEN 1 LINE pb
    OFF:
    GEN 1 line opens.  AC bus 1 is powered by Gen 2 through Bus tie.  Seperate circuit supplies power from GEN 1 to one fuel pump in each cell
  11. EMER ELEC PWR Panel
    Rat & Emer GEN Fault Light
    Illuminates Red if emergency gen is not supplying power when AC Bus 1 and 2 not powered
  12. EMER ELEC PWR Panel
    MAN ON pb guarded
    Auto
    • Rat automatically extends if
    • AC Bus 1 and 2 not powered and A/C >100 kts
  13. EMER ELEC PWR Panel
    MAN ON pb guarded
    Pressed
    • Manual Rat extension
    • Couples emergency generator when Blue Pressure is sufficient

Card Set Information

Author:
obinvb
ID:
191650
Filename:
320 Lights and Switches
Updated:
2013-01-08 02:15:44
Tags:
JB
Folders:

Description:
JB SPV
Show Answers:

What would you like to do?

Home > Flashcards > Print Preview