test 2

Card Set Information

Author:
class35
ID:
199145
Filename:
test 2
Updated:
2013-02-09 17:57:27
Tags:
PPE safety hozes nozzles
Folders:

Description:
test 2
Show Answers:

Home > Flashcards > Print Preview

The flashcards below were created by user class35 on FreezingBlue Flashcards. What would you like to do?


  1. NFPA 1500
    FD OSHA regulations
  2. NFPA 1403
    Live fire training
  3. How much does water weigh?
    8.33 lbs/gal
  4. What is the pressure of water at rest?
    static pressure
  5. The pressure remaining in a system while water is flowing at a second location
    residual pressure
  6. 16-48" diameter
    widely spaced
    hydrants not typically connected
    Primary feeders
  7. hydrants are rated by___
    • THE SIZE OF THE MAIN they are connected to
    • GPM of water they will flow
  8. How often are hydrants tested in SLC?
    at least once/year
  9. how much of a radius is rquired around a hydrant?
    3 feet
  10. What color is a hydrant cylinder equipped with National Standard Steamer outlets
    yellow
  11. What do black hydrant caps indicate?
    It is connected to a sprinkler system and pumping from it may compromise that system
  12. What type of water movement system does SLC use?
    combination of gravity and pump
  13. What color of hydrant bonnet will be connected to a 6" main?
    red
  14. 1500
    FD OSHA standards
  15. 1975
    Station/work uniforms
  16. 1977
    wildland FF
  17. 1951
    technical rx
  18. 1991
    Hazmat vapors
  19. 1992
    hazmat liquids
  20. 1971
    PPE for stuctural FF
  21. 1851
    care and maintainance for structural FF
  22. Triggering mechanisms for changes to PPE
    significant injuries or death
  23. who tests changes to equipment?
    3rd PARTY TESTING laboratories
  24. 2007 changes to 1851
    Addition of DRD
  25. 2008 revision to 1851
    max shelf life/service life

    (SLC=7 years)
  26. PPE equipment defined by:
    primary use, the hazard the user is protected from
  27. Types of PPE used by SLC
    • STATION WEAR/MEDICAL
    • SWIFTWATER RX
    • HAZMAT
    • TECHNICAL RX
    • WILDLAND
  28. water rx-contains BREAKAWAY TETHER SYSTEM they become
    ENTRAPPED OR SUBMERGED
  29. PFDs are for:
    all operating w/in the hazard area
  30. AUX STATIONS
    • 4
    • 9
    • 13
    • 14
  31. HAZMAT LEVEL A
    highest.  vapor protection. fully encapsulated
  32. HAZMAT B
    encapsulating.  liquid protection
  33. HAZMAT C
    nonencapsulating.  no scba
  34. HAZMAT D
    Structural FF.  may be jumpsuit
  35. TPP
    TPP/2= TIME TO 2ND DEGREE BURN
  36. RPP
    RPP X 2=TIME TO 2ND DEGREE BURN
  37. THL (TOTAL HEAT LOSS)
    • MIN. 205 WATT/METER SQUARED
    • PASS/FAIL
  38. EARFLAP TTP
    20
  39. hood ttp
    20
  40. GLOVES TTP
    35.  must extend 2" past wrist
  41. Boots must have
    • puncture resistant shank
    • protective toe cap
    • 10" high
  42. turnouts protect from:
    • ABRASION/PHYSICAL DAMAGE
    • FLAME IMPINGEMENT-outer layer
    • STEAM-middle
    • RADIANT/CONDUCTIVE HEAT-inner
  43. bunker ttp
    35
  44. 1981
    SCBA
  45. LOW PRESSURE CYLINDERS
    • 45' AT 2216 PSI
    • THEORETICAL WORKING TIME-30 MINS
    • ACTUAL 15-20
  46. LOW PRESSURE CYLINDER WEIGHS:
    • 8 LBS EMPTY
    • 11 LBS 10 OZ FULL
  47. HP CYLINDERS CONTAIN:
    • 66' AIR AT 4500 PSI
    • THEORETICAL WORKING TIME OF 45 MINS
    • ACTUAL-25-35 MINS
  48. HP CYLINDER WEIGHS:
    • 9 LBS 7 OZ EMPTY
    • 14 LBS 12 OZ FULL
  49. DAILY PRESSURE CHECK SHOULD BE AT:
    90% (1800 PER SLC POLICY AND 4000 PSI)
  50. ICM=
    INTERGRATED CONTROL MODULE
  51. ANALOG GUAGE ON ICM SHOULD READ
    100 PSI WHEN ON AIR
  52. GREEN BUTTON ON ICM
    • ILLUMINATION OF ICM
    • MODE SHIFT
  53. 1982
    PASS
  54. PASS PREALARM/ALARM DECIBAL REQUIREMENTS
    80/95
  55. SCBA check policy
    • 05-11.
    • PSI
    • ICM activates
    • audi alarm sounds
  56. 5" hose load requirements:
    900'
  57. 2.5" hose load requirements
    900'
  58. 1 3/4 preconnected bumper line hose load requirements
    100'
  59. transverse lines
    • 200' front control nozzle
    • 250' rear smooth bore nozzle
    • flat load
  60. carona 1 3/4" bundle
    100' with smooth bore nozzle attached
  61. HOSE IS LITERALLY A 
    FF's LIFELINE
  62. HOSE CONSTRUCTION
    • WRAPPED
    • WOVEN
    • BRAIDED
  63. ATTACK HOSE IS HOW BIG

    WHAT IS IT TESTED AT
    1.5" OR BIGGER

    300 IN SLC
  64. MDH IS WHAT DIAMETER

    NFPA REQUIREMENT
    2.5-3"

    400'
  65. SUPPLY HOSE (LDH) DIAMETER

    MAX PRESSURE
    3.5-5

    185 PSI
  66. LDH WEIGHS

    NFPA REQUIREMENT
    1 LB/FT

    800'
  67. TYPES OF HOSE DAMAGE
    • MECHANICAL
    • THERMAL
    • ORGANIC
    • CHEMICAL
  68. COUPLINGS SHOULD BE CLEANED IN WATER AND____
    EXCERCISED
  69. Lugs on couplings are called-

    which is longer-male or female?
    ROCKERS

    male
  70. indented hole
    recessed lug
  71. what kind of lugs do storz have?
    rocker
  72. what is the indicator called where threade starts?
    HIGBEE CUTS
  73. HOSE TESTING CONSISTS OF: