Genral Fire 2

Card Set Information

Author:
drankin1972
ID:
251628
Filename:
Genral Fire 2
Updated:
2013-12-14 12:46:44
Tags:
fire
Folders:

Description:
fire
Show Answers:

Home > Flashcards > Print Preview

The flashcards below were created by user drankin1972 on FreezingBlue Flashcards. What would you like to do?


  1. ____ is the resignation of gases that have risen and encountered fresh air
    Roll-over
  2. ____ is the minimum temperature in which a substance is heated to start combustion
    piloted ignition temperature
  3. Theoretical fire flow is
    Area in Square feet/3
  4. Atria needs to be sprinkled if ___ above the floor
    55ft
  5. _____ is a series of closely spaced beams, caries heavy loads
    grillage
  6. Square feet area per person apartment
    200
  7. board of nominal thickness
    2"
  8. Responsible for the layout and design of the site
    civil engineer
  9. Used at times for concrete roofs
    folded plate
  10. Rigid frame spans
    100ft
  11. Steel used to support roofs at a height of ___ft does not need protection
    20-30ft
  12. External force that acts on a structure
    Loads
  13. internal forces that resist the load
    stress and strain
  14. The maximum number of stories for a residential TYPE-1 building
    100 stories
  15. A wall designed to limit the spread of fire and which extends partially down (usually no more than 20% of the height of the compartment) from the underside of the roof
    draft curtain
  16. Horizontal exits usually have a __hr rating
    2hr
  17. A JOIST which parallels floor/roof beams and is used to create an opening
    headers
  18. WOOD MEMBERS USED TO SUPPORT THE ROOF SHEETING AND LOADS
    RAFTERS
  19. Which type of wall would be used as a foundation wall used in excavations and is heavily reinforced
    Slurry wall
  20. WHICH CODE IS A MAINTENANCE CODE
    FIRE CODE
  21. Which type of roof presents the greatest hazard for firefighters conduction roof operations
    foam core
  22. _____ is heat absorbing capacity
    specific heat
  23. _____ is a materials ability to resist flame spread
    radiant flux
  24. Time frame believed to pass before a building flashes
    15 minutes
  25. Hazard with post-tensioned concrete
    fire can cause collapse because floors or beams rest on falsework until weight is transferred to colomns
  26. Chemicals that can corrode concrete
    Chlorine and salt
  27. Concrete in fire resistive construction serves two purposes:
    • resists compression
    • protects the tensile strength of steel
  28. Pump test in the month of ___
    January

What would you like to do?

Home > Flashcards > Print Preview