PsAndCs Tab Separated.txt

Card Set Information

Author:
Anonymous
ID:
265330
Filename:
PsAndCs Tab Separated.txt
Updated:
2014-03-06 11:20:19
Tags:
Ps Cs 1603
Folders:

Description:
Ps & Cs 1603
Show Answers:

Home > Flashcards > Print Preview

The flashcards below were created by user Anonymous on FreezingBlue Flashcards. What would you like to do?


  1. C-1
    • IR High > 20%
    • 1/2
    • Block Auto and Manual Rod Withdrawal
  2. C-2
    • PR High > 103%
    • 1/4
    • Block Auto and Manual Rod Withdrawal
  3. C-3
    • OT delta T Rod Stop & Turbine Runback
    • 3% below Trip Setpoint
    • 2/4
    • Block Auto and Manual Rod Withdrawal 
    • Runback
  4. C-4
    • OP delta T Rod Stop & Turbine Runback
    • 1% below Trip Setpoint
    • 2/4
    • Block Auto and Manual Rod Withdrawal 
    • Runback Turbine
  5. C-5
    • Auto RodStop
    • PT-1-73 <15%
    • 1/1
    • Block Auto Rod Withdrawal
  6. C-7
    • Load Rejection
    • PT-1-72 senses Load Decrease > 10%
    • in 2 minutes
    • 1/1
    • Arm Steam Dumps in the Tave Mode
  7. C-9
    • Condenser Available
    • Condenser Pressure < 3.5 psia 
    • CCWP Racked in and closed
    • 2/2 on 1/3
    • Enables Steam Dumps
  8. C-11
    • Control Bank D Stop
    • 220 Steps
    • 1/1
    • Blocks Auto Rod Withdrawal
  9. C-20
    • AMSAC Interlock
    • > 40% Rx Power Equivalent
    • 2/2 PTs
    • Arms ATWS mitigation system actuation circuit.
  10. P-4
    • Reactor Trip & Bypass Breakers Open
    • or not Racked In
    • 2/2 (either train)
    • Blocks Auto SI Reset
    • Trip Turbine Generator
    • Input to FWI Logic
    • Arms Steam Dumps
  11. P-6
    • Intermediate Range > 10-4%
    • 1/2
    • Allows Block of SR Trip
  12. P-7
    • At Power
    • >P10 or P-13
    • 1/2
    • Enables 7 at power Rx Trips
  13. P-8
    • Power Range >35%
    • 2/4
    • Enable single loop low flow trip
  14. P-9
    • Power Range >50%
    • 2/4
    • Blocks Rx Trip on Turbine Trip
    • above P-7 but below P-9
  15. P-10
    • Power Range >10%
    • 2/4
    • Blocks SR Trip
    • Allows Block of IR and PR Trip & IR Rod Stop
    • Input to P-7
  16. P-11
    • Pressurizer Pressure <1970 psig
    • 2/3
    • allows block of PZ steamline low pressure SI opens cla isolation valves > P-11
  17. P-12
    • Tave <540
    • 2/4
    • Blocks Steam Dumps
  18. P-13
    • Turbine First Stage Pressure
    • >10 % Load Equivalent
    • 1/2 PTs
    • Input to P-7
  19. P-14
    • S/G Level >81% Narrow Range
    • 2/3 on any S/G
    • Trips Turbine
    • Trips MFPTs
    • FWI Signal

What would you like to do?