T-6A Starting Pressurization Fuel Runway.txt

Card Set Information

Author:
nde
ID:
286852
Filename:
T-6A Starting Pressurization Fuel Runway.txt
Updated:
2014-10-23 22:27:28
Tags:
6A Operating Limitations Starting Pressurization Fuel Runway
Folders:

Description:
T-6A Operating Limitations- Starting, Pressurization, Fuel, and Runway
Show Answers:

Home > Flashcards > Print Preview

The flashcards below were created by user nde on FreezingBlue Flashcards. What would you like to do?


  1. Starter Limit _____ Seconds
    20
  2. Wait ____ Sec, ______ Min, _____Min, _____Min after each start attempt
    30, 2, 5, 30
  3. Maximum ITT ______ degC for ________ Sec (Do Not Attempt Restart)
    1,000, 5
  4. Maximum Oil Pressure _______ PSI
    200
  5. Minimum Oil Temperature_______ degC
    -40
  6. Minimum Battery Voltage _______ V
    23.5
  7. Normal Above 18,000 FEET MSL _____ +/- _____ PSI
    3.6 +/- 0.2
  8. Overpressurization Valve Opens ______ PSI
    4.0
  9. Normal Recovery Fuel _____ Pounds
    200
  10. Minimum Fuel______ Pounds ( _____ Pounds Solo)
    150, 200
  11. Emergency Fuel _____ Pounds ( ____ Pounds Solo)
    100, 100
  12. Minimum Fuel for Aerobatics _____ Pounds per side
    150
  13. Minimum Runway Length ______ Feet
    4,000
  14. Minimum Runway Width ______ Feet
    75