NEETS 16.txt

Card Set Information

Author:
bc901
ID:
286904
Filename:
NEETS 16.txt
Updated:
2014-10-24 01:28:03
Tags:
xyz
Folders:

Description:
xyz
Show Answers:

Home > Flashcards > Print Preview

The flashcards below were created by user bc901 on FreezingBlue Flashcards. What would you like to do?


  1. _______________ is test equipment that has the capability, without modification, to generate, modify, or measure a range of parameters of electronic functions required to test two or more equipments or systems of basically different design.
  2. GPETE
  3. ________________ is specifically designed to generate, modify, or measure a range of parameters of electronic functions of a specific or peculiar nature required to test a single system or equipment.
  4. Special-purpose electronic test equipment (SPETE)
  5. CALIBRATED label, has ______ lettering and a ______background and comes in two sizes
  6. black, white
  7. The CALIBRATED—REFER TO REPORT label, has ______ lettering and a ______ back ground.
  8. red, white
  9. SPECIAL CALIBRATION labels have _______lettering and a _______background
  10. black, yellow
  11. INACTIVE—CALIBRATE BEFORE USE label has ________ lettering and a _______ background.
  12. green, white
  13. CALIBRATION NOT REQUIRED has ________ letters and a _______ background
  14. orange, white
  15. REJECTED—REFER TO ATTACHED TAG label is placed on the instrument and all other servicing labels removed. This label, has ________ letters and a ______ background.
    black, red
  16. CALIBRATION VOID IF SEAL BROKEN label, has _______ letters and a _______ background.
    black, white
  17. If you expect voltage to exceed ______ volts, wear rubber gloves.
    150
  18. Observe the following procedures when measuring voltages in excess of 300 volts:
    Turn off the equipment power.
  19. Short-circuit or ground the terminals of all components capable of retaining a charge.
  20. Connect the meter leads to the points to be measured.
  21. Remove any terminal grounds previously connected.
  22. Turn on the power and observe the voltage reading.
  23. Turn off the power.
  24. Short circuit or ground all components capable of retaining a charge.
  25. Disconnect the meter leads.
  26. The CALIBRATED label, with ________ lettering on a _______ background, indicates the instrument to which it is attached is within tolerance on all scales.
  27. black, white
  28. The CALIBRATED—REFER TO REPORT label, with ______ lettering on a _______background, is used when actual measurement values must be known to use the instrument
  29. red, white
  30. The SPECIAL CALIBRATION label, with ______ lettering on a ______background, is used when some unusual or special condition in the calibration should be drawn to your attention.
  31. black, yellow
  32. The __________ label indicates that you should calibrate the test and measuring instrument instead of sending the instrument to a calibration facility.
  33. User calibration
  34. The ________________ label is used when a piece of test equipment due for recalibration will not be used for some time in the future.
  35. INACTIVE—CALIBRATE BEFORE USE
  36. The ____________ label is used on test instruments listed in the Metrology Requirements List (METRL) as not requiring calibration
  37. CALIBRATION NOT REQUIRED
  38. The _________ label is attached to a test instrument that fails to meet the acceptance criteria during calibration and cannot be repaired
  39. REJECTED
  40. The ____________________ label is placed over readily accessible adjustments to prevent tampering by the user when such tampering could affect the calibration
  41. CALIBRATION VOID IF SEAL BROKEN
  42. The ____________ is used for precise measurement of resistance
    WHEATSTONE BRIDGE
  43. The _________________ is used for measuring an unknown capacitance
    CAPACITANCE BRIDGE
  44. An ___________ is used to find the value of an unknown inductance
    INDUCTANCE BRIDGE
  45. The common types of portable tachometers are the _________ and the _________
    CENTRIFUGAL, CHRONOMETRIC
  46. _________meters operate from their own power sources
  47. Self-excited
  48. ____________ meters get their power from the circuit to which they are connected
  49. Externally excited

What would you like to do?