  1. Maximum allowed corrosion rate when performing an On-stream inspection in lieu of an Internal (in ipy)
    0.005 ipy
  2. Ratio of endurance limit stress to ultimate tensile stress for CS
    0.4-0.5
  3. Static head factor (psig per height of water in feet)
    0.433 psig/ft
  4. Joint efficiency when using full RT on a type 1 joint
    1.0
  5. Joint efficiency when evaluating corroded area away from a weld by greater of: 1" or 2t
    1.0
  6. The # of additional RT's required when a spot RT has a defect
    2
  7. Number of tension tests required to qualify a WPS
    2
  8. # of bend tests required to qualify a welder  or welding operator in 1G-4G positions
    2
  9. Minimum RT film density allowed for the weld & IQI
    2.0
  10. Minimum # of exposers required to RT 360 deg of a weld using double-wall technique, double wall viewing. (elliptical shot)
    2
  11. Minimum # of exposers required to RT 360 deg of a weld using double-wall technique, single-wall viewing
    3
  12. Number of test bars required in each set of impact test specimens
    3
  13. When using a shim under a hole-type IQI, the number of sides of the IQI that must be seen in the RT image
    3
  14. Current safety factor of ASME section 8
    3.5
  15. Pre- 2000 safety factor of ASME section 8
    4.0
  16. number of bend tests required to qualify a welder or welding operator in 5G & 6G positions
    4
  17. number of bend tests to qualify a WPS
    4
  18. Maximum RT film density allowed for the weld & IQI
    4.0
  19. Maximum chloride content in hydro test water when testing 300 series SS (PPM)
    50 ppm
  20. RT film density range- allowed for the weld and IQI when using a gamma ray source
    2.0-4.0
  21. Design- recommended resistance of grounding systems
    5 ohms
  22. NDE- weight used to check magnetic strength of an AC yoke
    10 lbs
  23. Design- maximum resistance allowed of grounding systems
    25 ohms
  24. NDE- Min angle of eye-to-part to count as a visual exam
    30°
  25. NDE- weight used to check magnetic strength of a DC yoke or permanent magnet yoke
    40 lbs
  26. NDE- minimum light intensity when performing VT
    100ft-candles
  27. NDE-minimum light intensity when performing non-fluorescent MT of PT exams
    100-ft candles
  28. NDE- minimum black light intensity when performing MT or PT fluorescent exams
    1000 mW/cm2