DC

Home > Preview

The flashcards below were created by user beukelman on FreezingBlue Flashcards.


  1. Where is the DC Deck located inside the ship?
    Main deck, frame 0-338
  2. Where is Repair 2 located and what is its Area of Responsibility?
    • Location: Frame 97 (Ship Store P-way)
    • Area of Responsibilities: Frame 0-174 (inside the ship), Focasle to Amidships (topside),
    • Including the Fwd Superstructure becomes a Secondary DC Central in the event CCS has to be evacuated
  3. Where is Repair 3 located and what is its Area of Responsibility?
    • Location: 2nd deck at Frame 410 (Laundry)
    • Area of Responsibilities: Frame 300- Aft (inside ship), from Amidships to the Fantail. (Outside the ship) including the Aft Superstructure
  4. Where is Repair 5 located and what is its Area of Responsibility?
    • Location: Frame 206 (Mess Line P-way)
    • Area of Responsibilities: DC Deck between frames 174 – 300, including MER 1, MER 2, AUX 1, AUX 2.
  5. Name 11 Repair Locker Kits:ABCCDDEEEFGIJPPPPRSSW
    • Adapters Kit
    • Banding Kit
    • CPS Repair Kit
    • CBR Monitoring Kit
    • Dewatering Kit
    • De-smoking Kit
    • Electrician Kit
    • Emergency Lighting Kit
    • Emergency Comms Kit
    • F/F Access Equipment Kit
    • Gas Free Kit
    • Investigator Kit
    • Jubilee Pipe Patching Kit
    • Plugging Kit
    • Pipe patching Kit
    • PECU Kit
    • Portable Pump Kit
    • Repair Locker Tool Kit
    • Shoring Materials
    • Shoring Tool Kit
    • Welding Kit

    • How many Fire Pumps are there and what are they rated at?
    • 6 Pumps provide 1000 GPM @ 150 PSI
  6. Where are the fire pumps located?
    • VCHT
    • AUX1
    • MER1
    • MER2
    • SA
    • 3GEN
  7. Starboard Fire main Loop
    • #2 - AUX 1
    • #4 - MER 2
    • #6 - 3 GEN
  8. Port Fire main Loop
    • #1- FWD VCHT
    • #3 - MER 1
    • #5 - Shaft Alley
  9. What type of Fire Main do we have?
    Vertical Offset Loop
  10. How many Zebra Valves does the Fire Main have and where are these valves located?
    2 Zebra Valves, Frame 45 (outside the Fwd Boatswain Mate Locker) and Frame 410 (upper level, 3 GEN)
  11. Explain why we have these 2 Zebra Valves
    Having these 2 Zebra Valves, one forward and one aft, allows to segregate the Fire Main into 2 separate sides, giving the added survivability, that should one side take a hit, the other side remains unharmed.
  12. What deck is the Starboard/Port Loop on?
    The Starboard Loop runs on the DC Deck and the Port Loop runs on the 3rd Deck.
  13. What systems use the Fire Main? ABCCDFMMMRSVVV
    • AFFF Stations
    • Berthing Sprinklers
    • Combat Systems Equipment
    • Countermeasure Wash down
    • Decon Station Showers
    • F/O Tank Seawater Compensating System
    • Magazine Sprinklers
    • Main & Secondary Drainage System
    • Main Machinery Cooling
    • Reverse Osmosis Desalinators
    • Steering Gear Cooling
    • VCHT System
    • Vital Area Perimeter Sprinklers
    • VLS Deluge Flooding System
  14. How many Fire Main Shore Connection Stations are there and where are they located?
    There are 4 shore connection stations provided on the O1 Level Weather Deck, both Fore and Aft, and Port and Starboard, to allow shore/alternate water when the ships pumps are secured or disabled. Each Station consist of a series of four 2 ½ inch hose valves manifolded together feeding into a riser which connects into the Fire Main via a manually operated cutout valve and check valve.
  15. What type of AFFF System does Hopper have and how many stations are there?
    Type 3 Balanced Pressure Proportioning System, 2 Stations, 1 forward and 1 aft
  16. How many AFFF hoses are there onboard?
    20

    • The primary use of AFFF is for what type of fire?
    • Bravo
  17. AFFF can also be used to fight what kind of fires?
    Alpha and Charlie
  18. AFFF is mixed with Sea Water at what percentage?
    6% Concentrate to 94% Sea Water
  19. What Main Engineering spaces have AFFF Bilge Sprinklers?
    AUX-1, MER-1, MER-2, 3-GEN
  20. How many gallons of AFFF Concentrate does each AFFF Tank hold?
    600 Gallons of AFFF tank per station per Tank
  21. How many gallons of AFFF Concentrate does each station have in reserves?
    300 gallons of reserve AFFF concentrate (60) Five gallon drums
  22. What does the Blue & Red piping indicate
    AFFF Concentrate
  23. What does the Red & Green piping indicate
    Finished Foam
  24. The AFFF Pump is rated at how many gallons per minute?
    65 +/-5 gallons per minute
  25. How far apart are the Emergency AFFF Hose connections on the AFFF loop?
    Roughly 50 feet apart or one in between each transverse frame
  26. Where are the AFFF Cross Connects?
    Just aft of frame 220 on the port and starboard side
  27. What 2 other locations have AFFF Sprinklers
    The Focasle and the Flight deck
  28. What toxic gas can form from a Seawater/AFFF mixture
    H2S (Hydrogen Sulfide)
  29. What is the ventilation and soak time after Halon has been discharged?
    15 Minutes each
  30. What gas actuates the Halon system
    CO2
  31. How many pressure switches are utilized on a Halon board for a manned Main Engineering Space
    4
  32. What is that 4th pressure switch for
    Toxic Gas Dampeners and Air Lock Air Supply
  33. How many pressure switches are utilized on a Halon board for an unmanned space
    3
  34. The time delay for a manned space is how long
    60 seconds +/- 10
  35. The time delay for an unmanned space is how long
    30 seconds +/- 5
  36. Halon is actually discharged for how long in the space
    10 seconds
  37. Halon can be remotely activated from this console for a GTM
    PACC
  38. Halon can be remotely activated from this console for A GTG?
    EPCC
  39. At what temperature does Halon turn into a toxic gas
    900 Degrees
  40. What are common toxic gases
    Hydrogen Fluoride and Hydrogen Bromide
  41. What is the name of the grey and white stripped handle used to override the time delay device
    Time Delay Bypass Valve
  42. What indication do you get at the time delay once CO2 has arrived at it?
    The little red plunger pops out
  43. Name the spaces that have Halon?
    Paint locker
  44. Where is the Fresh Water Fire Fighting Pump
    AUX-1
  45. What is the purpose of the Fresh Water Fire Fighting System
    To prevent corrosion and to minimize the residual water as opposed to having a sea water fire fighting system to combat Charlie fires.
  46. What is the Fresh Water Fire Fighting Pump rated at
    70 GPM @ 70 PSI
  47. How many hose reels does the Fresh Water Fire Fighting System have and where are they located?
    • 6 hose reels total
    • Outside Sonar Control
    • Outside CSER 2
    • Outside CSER 3
    • Outside CCS
    • Outside CIC, Port P-way
    • Outside CIC, STBD P-way
  48. How many MOPP levels are there?
    4
  49. What is the name of the personal dosimeter issued out at MOPP 2?
    IM-270
  50. Name one of the 4 self aids that are issued out my medical at MOPP 2?
    Atropine, 2PAM-Chloride, Diazepam, and NAPP Tablets
  51. What does MOPP stand for?
    Mission Oriented Protective Posture
  52. Where are the Decon Stations located?
    • Fwd: Port Castleway / Admin P-way
    • Aft: Flight deck / Aft airlock P-way
  53. What are the 4 compartments inside the Decon Stations?
    • Outer Clothing Undressing Area (OCUA)
    • Inner Clothing Undressing Area (ICUA)
    • Deluge Shower
    • Contamination Purge Lock (CPL)
  54. What type of Gas Mask do we use?
    MCU-2/P
  55. How long will your C2 Canister last in a non-contaminated environment?
    60 Days
  56. What is the name of your suit that you wear in a CBR environment?
    ACPG (Advanced Chemical Protective Garment)
  57. How long can you wear your ACPG in a non-contaminated environment?
    45 days
  58. What does IPDS Stand for?
    Improved Point Detection System
  59. What does JBPDS stand for?
    Joint Biological Point Detection System
  60. Where is the JBPDS system located and what does it test for?
    • 05 Level
    • (V & G) Nerve Agents and (H) Blister Agents
  61. What color does G, V and H agents show on M8/M9 Paper
    • V- green
    • G- yellow
    • H- red
  62. WDCM
    Countermeasure Wash down System
  63. What is the purpose of the WDCM System?
    Provides protection against CBR contamination agents by creating a film of water that flows over the skin of the ship, preventing any Chemical or Biological Agents from sticking to the ship and washing the contaminants away and overboard.
  64. Name the 4 WDCM Zones?
    • Zone 1- Focasle
    • Zone 2- Fwd Superstructure
    • Zone 3- Aft Superstructure and Aft VLS
    • Zone 4- Flight Deck
  65. Where are the 3 locations that a WDCM Zone can be activated?
    DC Console in CCS, Bride Control Panel, and at the SOPV
  66. At what MOPP Level would you activate all WDCM zones continuously?
    MOPP 3
  67. At what MOPP Level would you activate all WDCM zones for a specific period of time?
    MOPP 4
  68. What is the length of the ship?
    505 Feet
  69. What is the Beam?
    • How wide the ship is
    • 66.5 Feet
  70. What is Ship’s displacement?
    9600 Long Tons
  71. What is the draft?
    The distance from the water line to the keel (32.5ft)
  72. What is the freeboard?
    The distance from the waterline to the weather deck
  73. What is a moment?
    A temporary roll to either the port or starboard side
  74. What is a List?
    A permanent angle of heel
  75. What makes it a Fire Zone?
    The bulkhead has a special fire resistant lagging on it
  76. Explain the parts of the bulls eye? 2-338-2-L
    • 2- Indicates the Deck,
    • 338-Indicates the forward most frame,
    • 2-Indicates the relation to centerline,
    • L- indicates what type of compartment it is
  77. What type of compartments do letters A,E,M,Q,L and T represent?
    • A-Storeroom
    • E-Engineering
    • M-Magazine
    • Q-Miscellaneous or Fan room
    • L-Living Space or Passageway
    • T-Trunk
  78. How long will photo luminescent tape stay lit after the power goes out?
    1 Hour
  79. Name the basic Material conditions of Readiness?
    X-RAY, YOKE, ZEBRA, MOD-ZEBRA
  80. What is the name of the device that melts for automatic operation?
    Fusible Link
  81. At what temperature does the fusable link melt?
    360 Degrees
  82. What does APC stand for?
    Aqueous Potassium Carbonate
  83. Where are the 4 CPS Zones/fire boundries?
    • Zone 1: Frame 0-126
    • Zone 2: Frame 126-254
    • Zone 3: Frame 254-370
    • Zone 4: Frame 370-aft
  84. What are the 2 different types of zones?
    Total Protection and Limited Protection
  85. What are the 3 different types of air locks?
    Type 1, 2, and 3
  86. What is the normal internal psi of the ship?
    2-2.5 psi
  87. What ship psi range is considered a deficiency?
    1.5-0.5 psi
  88. What ship psi is considered a casualty?
    .5 -0 psi
  89. What is the P-100 rated at?
    100 GPM @ 83 PSI
  90. What is the Ram Fan rated at?
    2000 CFM
  91. What is the Box Fan rated at?
    3200 CFM
  92. What are the 2 sizes of PKP extinguishers?
    18 LBS & 27 LBS
  93. What is a CO2 extinguisher max effective discharge range?
    4-6 FT
  94. What is the max effective discharge range of an AFFF extinguisher?
    15 FT
  95. What are the 2 sizes of SCBA Bottles?
    30 – 45 min bottle
  96. The Scott EEBD is rated for how many minutes if your awaiting rescue?
    30 minutes
  97. What 4 indications will tell you that your bottle is low on air on your Scott SCBA?
    Lollipop Gage, Vibra-alert, Bottle gage, and the Bell
  98. What does EEBD stand for?
    Emergency Escape Breathing Device
  99. What is the ESP rated at?
    140GPM @ 70 ft. of discharge head
  100. What fluids should you not pump with an ESP?
    Oil, Fuel, Heavy Solvents
  101. What is the difference in a blue EEBD and an orange EEBD?
    Blue is for training only
  102. Name 4 types of pipe patches?
    Soft, Jubilee, EWARP, and Banding
  103. What does EWARP stand for?
    Emergency Water Activated Repair Patch
  104. What are the 2 EWARP sizes?
    2 inches x 5 feet and 4 inches X 15 feet
  105. What powers the box fan?
    115 volts of A/C
  106. Name 4 different types of dewatering equipment.
    Peri-Jet Eductor, P-100, Electrical Submersible Pump, S-type Eductor
  107. What main engineering spaces is a part of the Main Drainage Systems?
    • AUX 1,
    • MER 1,
    • MER 2,
  108. What spaces are apart of the Secondary Drainage system?
    3 GEN and Aft Steering
  109. Which spaces have eductors installed?
    Aft Steering , AUX 1, MER 1, MER 2, 3 GEN
  110. Which space has an ESP installed?
    3-GEN
  111. WILLIAM fittings
    are vital sea suctions, CPS zone ventilation fittings valves (serving vital equipment in manned spaces) and valves that must be open to maintain mobility and fire protection. WILLIAM fittings are open during all material conditions. They are secured only to control damage, contamination or to repair equipment served
  112. DOG ZEBRA
    fittings are secured when condition ZEBRA is set and whenever the ship is darkened. During Darken Ship they are closed to prevent light inside the ship from showing outside.
  113. Circle ZEBRA
    fittings are closed when condition ZEBRA is set. They may be opened with the permission of the CO during extended periods of general quarters
  114. Condition XRAY
    provides the least watertight integrity and the greatest ease of access throughout the ship.
  115. Condition YOKE
    provides a greater degree of watertight integrity than condition XRAY, but to a lesser degree than the maximum condition.
  116. Condition ZEBRA
    provides the greatest degree of subdivision and water-tight integrity to the ship. It is the maximum state of readiness for the ship's survivability system. Condition ZEBRA is set: Immediately and automatically when general quarters is sounded
  117. What is the primary damage control net?
    8880

Card Set Information

Author:
beukelman
ID:
311485
Filename:
DC
Updated:
2015-11-15 05:04:09
Tags:
usshopper
Folders:
esws
Description:
dc
Show Answers:

Home > Flashcards > Print Preview