  1. When using VNX Installation Assistant to register a VNX system, which three methods can you
    use to transmit the registration and configuration package to EMC?

    A. Automatic upload, manual upload utility, default email client
    B. Automatic upload, default email client, Powerlink upload page
    C. Manual upload utility, Powerlink upload page, SPcollect
    D. Automatic upload, SPcollect, default email client
    A
  2. What command is used to confirm that the primary Data Mover has a standby relationship with
    another Data Mover?

    A. server_sysconfig
    B. setup_slot
    C. nas_server
    D. server_setup
    C
  3. What is the VNX default failover policy for a Data Mover?

    A. Auto
    B. Manual
    C. Retry
    D. Verify
    A
  4. What is the minimum EMC-recommended ratio of standby Data Movers to production Data
    Movers?

    A. 1:3
    B. 1:2
    C. 1:1
    D. 1:7
    A
  5. Which is a requirement for configuring a primary and standby Data Mover for failover operation?

    A. Highest server_# used for standby
    B. Identical I/O modules
    C. Four-port network adapter
    D. One standby Data Mover (DM) per primary DM
    B
  6. The Data Mover in slot_2 has been configured as a primary Data Mover (DM). DMs in slot_3 and
    slot_4 are standbys. What would be the result of a slot_2 failure?

    A. One of the standby DMs will take over, but if the second DM fails, there will be no further
    failover operations.
    B. Server_2 will be halted and the Unisphere event log will indicate that an invalid configuration
    has prevented a failover operation.
    C. One of the standby DMs will take over. In the event of another failure the remaining standby
    DM will take over.
    D. Only a standby server containing a valid copy of the configuration will perform a takeover
    operation.
    A
  7. You have been tasked to run a test of dual Control Station high-availability.
    Which command would you run from the primary Control Station?

    A. cs_standby -failover
    B. server_standby server_2 -a mover
    C. cs_standby -takeover
    D. server_standby server_3 -a mover
    A
  8. Which will be displayed by running the df command on the primary Control Station?

    A. NFS exports
    B. Mounted NAS partitions
    C. Mounted SDA partitions
    D. CIFS mount points
    D
  9. How many private networks are used for each Control Station that is managing a fully populated
    DME?

    A. 2
    B. 1
    C. 3
    D. 4
    A
  10. Which Control Station commands can obtain more detailed information for umount?

    A.

    man umount
    umount --help
    info umount
    what is umount
    B.

    man umount
    umount /?
    info umount
    what is umount
    C.

    man umount
    umount --help
    server_info umount
    what is umount

    D.

    man umount
    umount --help
    info umount
    print umount
    A
  11. If the Data Movers are preconfigured for AUTO failover mode, how does the VNX respond to a
    primary DM failure?

    A. The active standby DM provides nondisrupted service.
    B. The standby DM immediately takes over the settings of the primary.
    C. The Control Station shuts down the primary DM and awaits action.
    D. The Control Station attempts to recover the failed DM.
    B
  12. What does "back end" mean when referring to a VNX File storage system?

    A. Storage subsystem
    B. Connections to the LCCs, DAEs and physical drives
    C. NAS clients in the production TCP/IP network
    D. Fibre Channel connection to the hosts
    A
  13. What does "front end" refer to in reference to VNX storage processors?

    A. Fibre Channel connection to the hosts
    B. Connections to the LCCs, DAEs and physical drives
    C. Storage subsystem
    D. NAS clients in the production TCP/IP network
    A
  14. Why must the USM Engineering mode be enabled in a VNX OE for Block upgrade?

    A. To cancel the upgrade
    B. To revert the upgrade
    C. To get debug information
    D. To override a failed rule
    D
  15. From where can you download VNX software?

    A. EMC Services Partner website
    B. EMC FTP site
    C. Engineering website
    D. Procedure Generator
    A
  16. Which tool is required for all VNX upgrades but is available only to EMC employees and partners?

    A. VNX Procedure Generator
    B. Unisphere Service Manager
    C. SPcollect
    D. VNX Installation Toolbox
    A
  17. You are on a customer site to perform a software upgrade on a VNX Unified storage system. You
    have worked with the customer to install USM on the system that has IP connectivity to the VNX
    system and the Internet. What is the behavior of the Download Software Updates Wizard in USM?

    A. It advises the user of the current versions of software on the system and then requires the user
    to navigate to Powerlink for the downloads of the appropriate software upgrade versions.
    B. The user must manually look for the current versions of software on the system and then must
    manually navigate to Powerlink for the downloads of the appropriate software upgrade versions.
    C. It advises the user of the current versions of software on the system and then connects the user
    to Powerlink for the downloads of the appropriate software upgrade versions.

    D. The user must manually look for the current versions of software on the system and then the
    wizard connects the user to Powerlink for the downloads of the appropriate software upgrade
    versions.
    C
  18. You are on a customer site to perform a software upgrade on a VNX Block storage system. You
    have worked with the customer to install USM on a system that has IP connectivity to the VNX
    system and the Internet. What is the behavior of the Download Software Updates Wizard in USM?

    A. It advises the user of the current version of VNX OE for Block software on the system and then
    connects the user to Powerlink for downloads of the appropriate versions of the VNX OE for Block
    upgrade software.
    B. It advises the user of the current versions of VNX OE for Block software on the system and
    requires the user to navigate to Powerlink for downloads of the appropriate versions of VNX OE
    for Block upgrade software.

    C. The user must manually look for the current versions of VNX OE for Block software on the
    system and must manually navigate to Powerlink for downloads of the appropriate versions of the
    VNX OE for Block upgrade software.
    D. The user must manually look for the current versions of VNX OE for Block software on the
    system and must manually connect to Powerlink for downloads of the appropriate versions of the
    VNX OE for Block and language pack software.
    A
  19. You are upgrading the VNX OE for File to a new version and choose to reboot the Data Movers
    during the upgrade. How long will the users lose access to their files?

    A. Access is lost for a time estimated by the USM tool.
    B. Access is lost for two minutes.
    C. Access to the files is never lost.
    D. Access is lost for a time estimated by the HealthCheck tool.
    A
  20. Which software operation is supported by USM?

    A. Install NAS code patches
    B. Fully cancel a VNX OE for File upgrade
    C. Install an enabler
    D. Download and install language packs
    C
  21. Image Upload
    You are upgrading the VNX OE for File and the VNX OE for Block storage systems in the same
    operation. You are currently in the VNX OE for File upgrade. What will happen as a result of
    pressing the Cancel button?

    A. The installation will pause.
    B. Only the Block upgrade will be cancelled.
    C. The Block and the File upgrade will be cancelled.
    D. The cancel operation will fail.
    A
  22. You are tasked with performing a DART patch upgrade on a VNX File storage system. What
    action would you take?

    A. Perform the upgrade from the Control Station CLI.
    B. Launch USM and use the System Software Wizard.
    C. Open Unisphere and navigate to the System Properties Software tab.
    D. Perform the upgrade using the VNX Installation Assistant.
    A
  23. A user logs in to USM and under the Hardware section sees a storage icon with a red X. What
    does this mean?

    A. Either the storage system or one of its components is failed.
    B. The storage system is unsupported.
    C. The storage system is unmanaged.
    D. The storage system is inaccessible.
    D
  24. A user logs in to USM and under the Hardware section sees a storage icon with a? What does this
    mean?

    A. The storage system is unsupported.
    B. The storage system is inaccessible.
    C. The storage system is unmanaged.
    D. Either the storage system or one of its components is failed.
    A
  25. You are working on a system with a faulted SPE power supply, and an alert is present in
    Unisphere. When can the related alert be deleted?

    A. After the issue has been resolved.
    B. Alerts cannot be deleted.
    C. The alert will delete automatically.
    D. After a storage processor reboot.
    A
  26. In the Unisphere Current Alerts screen, how do you obtain a full description about an alert?

    A. In the filter text box enter the event code, click the Filter icon, and select Search any column.
    B. Right-click the alert and export it to a file.
    C. Double-click on the alert.
    D. Select the alert and click the Help button.
    C
  27. What is a valid explanation for a single port on a 6 Gb SAS I/O module whose status light is OFF?

    A. The connected LCC has faulted.
    B. There is no transmit light in the optical cable.
    C. There is a failed disk in the enclosure.
    D. The SP is performing zero disk.
    A
  28. What does a green LED blinking at a constant rate indicate on a 3.5” disk drive?

    A. The drive is spinning up or down.
    B. The drive is performing self-diagnostics.
    C. The drive has I/O activity.
    D. Drive enclosure power is applied but the controller enclosure is down.
    A
  29. In Unisphere under System > Monitoring and Alerts, how do you determine current system health?

    A. In the Monitoring task pane, click the Storage System Connectivity Status link
    B. In the Monitoring task pane, click the Trespass LUN Status link
    C. In the Monitoring task pane, click the Fault Status Report link
    D. In the Monitoring and Alerts section, click the Alerts
    C
  30. How can users search for hardware issues on a VNX for File storage system using EMC
    Unisphere?

    A. Once logged in to Unisphere, use the drop-down list to select System > Storage Hardware for File
    B. Once logged in to Unisphere, use the drop-down list to select System > Storage Hardware for Block
    C. Once logged in to Unisphere, navigate to the dashboard section and select System > Storage
    Hardware for File
    D. Once logged in to Unisphere, navigate to the dashboard section and select System > Storage Hardware for Block
    A
  31. When using USM's Capture Diagnostic Data feature, where are the files automatically stored upon
    completion of this task?

    A. They are in the C:\EMC\repository folder located on the system running USM.
    B. They are automatically uploaded to EMC support if the system is registered.
    C. The user is prompted to either view them or upload them to EMC if ConnectHome is
    configured.
    D. They are automatically stored in the repository located on the VNX vault drives.
    A
  32. You are working on a VNX Unified system that has a fault LED illuminated on the DME. What
    action would you take to further analyze the system status?

    A. Perform a Data Mover failover operation to the standby Data Mover.
    B. Launch USM and perform a Verify Storage System operation.
    C. Install VNX Analyzer to capture the DME hardware status.
    D. Perform a background verify operation on the control LUNs.
    B
  33. You are working on a VNX Block system that has a fault LED illuminated on a DAE. What action
    would you take to further analyze the system status?

    A. Launch USM and perform a Verify Storage System operation.
    B. Install VNX Analyzer to capture the DAE hardware status.
    C. Perform a background verify operation on the system's LUNs.
    D. Trespass the system's LUNs to the peer storage processor.
    A
  34. You are working on a VNX Unified system that has a fault LED illuminated on the DME. What
    action would you take to further analyze the system status?

    A. Launch USM and capture diagnostic data from the system.
    B. Install VNX Analyzer to capture the DME hardware status.
    C. Perform a background verify operation on the control LUNs.
    D. Trespass the control LUNs to the peer storage processor.
    A
  35. You are working on a VNX Block system that has a fault LED illuminated on a DAE. What action
    would you take to further analyze the system status?

    A. Install VNX Analyzer to capture the DME hardware status.
    B. Perform a background verify operation on the system's LUNs.
    C. Launch USM and capture diagnostic data from the system.
    D. Trespass the system's LUNs to the peer storage processor.
    C
  36. You are working on a VNX Unified system that has a hardware fault on a storage processor and
    you need to determine which components of the SP are FRUs. What action would you take to get
    the needed information?

    A. Use the VNX Procedure Generator to view the specific VNX model’s illustrated parts guide.
    B. Access the Alerts section of Unisphere and review the details of the specific hardware fault
    alert.
    C. View the appropriate VNX installation guide VNX on Powerlink.

    D. Use the VNX Procedure Generator to generate an SP replacement procedure.
    A
  37. Your customer contacts you regarding an illuminated hardware fault LED on a VNX LCC
    component. Using ESRS you access the system with Unisphere and determine that the faulted
    LCC component needs to be replaced. Which action would you take to get the LCC part number
    for ordering a new replacement part?

    A. Use the VNX Procedure Generator and view the specific VNX model parts guide.
    B. Access the Alerts section in Unisphere and locate the specific alert for the faulted LCC.
    C. Launch Unisphere Service Manager and perform a system verification operation.
    D. Access the Hardware for File section of Unisphere and locate the faulted LCC.
    A
  38. Image Upload


    What happens when the user selects the indicated option within the VNX Procedure Generator?

    A. A PDF document is generated and displayed to the user for the associated activity.
    B. A Word document is both displayed and emailed to the user for the associated activity.
    C. A PDF document is produced with a link to a site where the user can build User Personalized
    Documentation.
    D. A Word document is produced with a link to a site where the user can build User Personalized
    Documentation.
    D
  39. Image Upload

    When using the VNX Procedure Generator to make a hardware replacement procedure, what will be the results of selecting the indicated link?

    A. A series of windows with drop-down lists is presented for the user to select the VNX model, storage type, and part to be replaced.
    B. A parts replacement PDF file is generated and emailed to the user who is running the VNX
    Procedure Generator.

    C. Unisphere Service Manager is launched with user-selectable drop-down lists for selecting part
    replacement activity.
    D. Unisphere Service Manager is launched to gather system information for producing a part
    replacement procedure.
    A
  40. Why would you boot to the utility partition?

    A. Reimage a corrupted boot image
    B. Run offline SPCollects
    C. Change Fibre Channel port speeds
    D. Restart the management server
    A
  41. A customer engineer (CE) has successfully powered up a factory-installed VNX Unified storage
    system. The CE now needs to configure the Control Station for network access.

    What is required of the PC running the VIA to successfully discover the Control Station?

    A. It must be on the same subnet as the Control Station.
    B. It must have a serial connection to the Control Station.
    C. It must be able to ping the Control Station before configuration.
    D. It must use the Control Station's hostname to make the initial connection.
    B
  42. Which system check is performed during the installation of a VNX File Unified system?

    A. Cable check
    B. SMTP validation
    C. Modem test
    D. DNS resolution
    C
  43. Which part is a Customer Replaceable Unit?

    A. Blower module
    B. Blade enclosure
    C. Control Station
    D. Storage processor
    A
  44. What does the server_route command configure?

    A. OSPF dynamic routes
    B. Blade dynamic routes
    C. Blade static routes
    D. RIPv2 static routes
    C
  45. An operator must shut down the standby Control Station CS1 on a VNX configured with dual
    Control Stations. What action, if any, does the operator need to take to allow management and
    monitoring of the VNX to continue when CS1 is offline?

    A. The operator needs to manually run the cs_standby command for the standby Control Station
    to assume the primary role.
    B. No action required; CS0 continues to operate with the primary Control Station role.
    C. The operator needs to manually run the cs_standby command to shut down the standby
    Control Station.

    D. No action is required; management and monitoring functions are not provided to the Celerra by the Control Stations.
    B
  46. Which VNX models use a disk processor enclosure (DPE)?

    A. VNX5500, VNX5800, VNX7600
    B. VNX5100, VNX5600, VNX7500
    C. VNX5300, VNX5600, VG10
    D. VNX5100, VNX5700, VNX5800
    A
  47. You are onsite for a DAE and drive upgrade for a VNX 7600 array. After inspecting SP Collects
    from the array you notice that the VNX has the following active configuration:



    -  1 x 2.5" DPE



    -  36 x 2.5" DAE's



    -  919 total drives



    -  914 bound data and hotspare drives



    -  6 empty slots

    How many additional 2.5" DAEs and drives can the array support?

    A. 3 x 2.5" DAEs, 81 drives
    B. 3 x 2.5" DAEs, 86 drives
    C. 6 x 2.5" DAEs, 81 drives
    D. 6 x 2.5" DAEs, 86 drives
    A
  48. Which VNX models support a SPE?

    A. 5700, 8000
    B. 5800, 7600
    C. 5600, 8000
    D. 5600, 7600
    A
  49. You are onsite for a DAE and drive upgrade for a VNX 5800 array. After inspecting the collections from the array you notice that the VNX has the following active configuration:
    1 x 2.5" DPE
    21 x 2.5" DAE's
    10 x 3.5" DAE's

    681 bound data and hotspare drives
    0 faulted drives
    2 unbound drives

    How many additional 2.5" DAEs and drives can the array support?

    A. 2 x 2.5" DAEs, 67 drives
    B. 2 x 2.5" DAEs, 76 drives
    C. 4 x 2.5" DAEs, 67 drives
    D. 4 x 2.5" DAEs, 76 drives
    A
  50. On a VNX Unified storage system, which file components are responsible for system
    management, access and failover?

    A. Control Stations 0 and 1; Data Movers 2 and 3
    B. Control Station 0; Data Mover 2
    C. Control Station 0; SPA,and SPB; first DAE
    D. DPE; Data Movers 2 and 3; SPA
    A
  51. Image Upload
    Which port is used to observe Power Up on the VNX8000?

    A. 7
    B. 6
    C. 4
    D. 3
    A
  52. You are about to install a VNX7600 Unified. Which components should be on-site and installed?

    A. At least one Data Mover Enclosure
    Disk Processor Enclosure
    At least one Control Station
    Optional Disk Array Enclosure

    B. At least one Data Mover Enclosure
    Optional Disk Array Enclosure
    Storage Processor Enclosure
    At least one Control Station

    C. Disk Processor Enclosure
    A least one Standby Power Supply
    At least one Data Mover Enclosure
    Optionally at least one Disk Array Enclosure
    D. At least one Control Station
    Storage Processor Enclosure
    Optionally at least one Disk Array Enclosure
    Disk Processor Enclosure
    A
  53. You are about to install a VNX8000 for File. Which components should be on-site and installed?

    A. At least one Control Station
    Storage Processor Enclosure
    At least one Data Mover Enclosure
    At least two Standby Power Supplies
    At least one or more Disk Array Enclosures
    B. At least one Control Station
    A least one Data Mover Enclosure
    Disk Processor Enclosure
    At least one or more Disk Array Enclosures
    At least two Standby Power Supplies
    C. Storage Processor Enclosure
    At least one Standby Power Supply
    At least one Control Station
    At least one Disk Processor Enclosure
    At least one or more Disk Array Enclosures
    D. At least one or more Disk Array Enclosures
    Disk Processor Enclosure
    At least one Standby Power Supply
    At least one Data Mover Enclosure
    At least one Control Station
    A
  54. In a VNX for File system, what is connected to the Control Station Eth1 port?

    A. Secondary Control Station
    B. Primary DM MGMT network
    C. Secondary DM MGMT network
    D. Customer Network for MGMT
    A
  55. Image Upload
    In an original balanced cabling configuration of a VNX5400, what is the enclosure number to which
    the large arrow at the top of the diagram is pointing?

    A. 1
    B. 0
    C. 2
    D. 3
    A
  56. After installing a MCx VNX for a new EMC customer, the system admin asks where the latest VNX documentation can be found. What is the correct location?

    A. support.emc.com
    B. powerlink.emc.com
    C. supportinfo.emc.com
    D. elabadvisor.emc.com
    A
  57. Which utility discovers and initializes a VNX, performs a health check, configures the control
    station and Data Movers, and allows for product registration?

    A. VNX Installation Assistant
    B. Unisphere Service Manager
    C. Unisphere Initialization Utility
    D. VNX Installation Toolbox
    A
  58. You are sent to a secure customer site to install a VNX, where the use of cell phones and mobile hot spots is prohibited. When you arrive you find that your VNX Installation procedure file is corrupted.

    Using one of the customer’s workstations where can a copy of the VNX installation procedure be
    found?

    A. mydocs.emc.com/VNX
    B. support.emc.com/VNX
    C. emc.com/engineering/VNX
    D. powerlink.emc.com/VNX
    A
  59. Where can customers obtain all documents related to the installation and maintenance of their
    VNX?

    A. https://mydocs.emc.com/VNX
    B. https://support.emc.com/VNX
    C. https://one.emc.com/VNX
    D. http://powerlink.com/VNX
    A
  60. A customer wants to use compression, deduplication and thin provisioning. Where are the
    software enablers located?

    A. VNX Installation Toolbox
    B. VNX Installation Assistant for File/Unified
    C. VNX Storage System Initialization Wizard
    D. Unisphere Server Utility
    A
  61. You are being sent to a customer site to replace a power distribution panel for a VNX7600. Where
    in the SolVe Desktop tool can a procedure for this activity be generated?

    A. Titan 40U and 40U-D cabinet Procedures
    B. Service Alerts, Support Materials and Part Guides
    C. VNX7500 Procedures
    D. VNX7600 Procedures
    A
  62. What should be installed/upgraded to get an updated version of the Pre-Upgrade Health Check (upgrd-ck) script?

    A. SolVe Desktop tool
    B. VNX Installation Toolbox
    C. Unisphere Service Manager
    D. Unisphere Initialization Utility
    A
  63. Which statement applies to the VNX w/MCx (VG10 and VG50) Gateway configuration?

    A. VNX w/MCx Gateway can use Symmetrix VMAX only
    B. VNX w/MCx Gateway can only use Symmetrix VMAX, VNX Block, and/or CLARiiON for the
    storage subsystem
    C. VNX w/MCx Gateway must be attached to the storage array through a SAN
    D. Storage subsystem cannot be used to provide storage to other hosts
    A
  64. Which worksheet can be used to collect data about operating environmental requirements for a
    VNX Gateway installation?

    A. Site Preparation
    B. Control Station Networking
    C. Various Configuration
    D. Private LAN
    A
  65. Which software tool is used for initializing, registering, and basic configuration of new VNX for File/Unified platforms?


    A. VNX Installation Assistant
    B. Unisphere Storage System Initialization Wizard
    C. E-Lab Advisor
    D. Unisphere Service Manager
    A
  66. How would you discover the appropriate network setting from the computer where the VNX
    Installation Assistant for File is running?

    A. Choose the “Select to use network settings from this client” option.
    B. Verify the MAC address from the Control Station sticker, and then reboot the Control Station.
    C. Select any other available MAC address to determine the network configuration.
    D. Search DNS for the Control Station's computer name and use the associated network settings.
    A
  67. Which account allows root access and cannot be disabled or deleted?

    A. nasadmin
    B. sysadmin
    C. sysadmin local account
    D. nasadmin global account
    A
  68. Using the Unisphere Storage System Initialization Wizard, what are valid data port network parameters for iSCSI connectivity on a VNX for Block system?

    A. IP address, subnet mask, gateway, and direct
    B. IP address, subnet mask, and gateway only
    C. SP A hostname, SP B hostname, and gateway
    D. VNX for Block does not support iSCSI connectivity.
    A
  69. When installing a new VNX Gateway system, which utility or tool can be used to install the VNX
    OE for File software?

    A. PuTTY
    B. Unisphere VNX Client
    C. VNX Installation Assistant
    D. Unisphere Service Manager
    A
  70. When installing a VNX for File, which subnet must be used?

    A. The same subnet as the Control Station public network interface
    B. The same subnet as the Control Station private network interface
    C. The same subnet as Domain Server public network interface
    D. The same subnet as the Data Movers public network
    A
  71. What is required to run VIA from a service laptop when configuring a VNX system?

    A. VNX and laptop must use the same subnet.
    B. VNX and laptop must use different subnets.
    C. Laptop must be connected via a serial connection.
    D. Laptop must be directly connected to the CS_0.
    A
  72. What is VIA used to configure?

    A. VNX File and Unified systems
    B. VNX File systems only
    C. VNX Unified systems only
    D. VNX Gateways
    A
  73. You are required to install ESRS on a newly installed VNX for Block array. Where can the latest
    version of the VNX Installation Toolbox be located?

    A. EMC Support
    B. E-Lab Advisor
    C. E-Lab Interoperability Matrix
    D. CCA
    A
  74. Which type of connection does the Control Station use for management?

    A. Ethernet public LAN
    B. Fibre Channel
    C. Ethernet private LAN
    D. Serial
    A
  75. What are the Alert Severity Types?

    A. Informational
    Warning
    Errors
    Critical

    B. Informational
    Warning
    Errors
    Debug

    C. Informational
    Warning
    Critical
    Debug

    D. Informational
    Errors
    Critical
    Debug
    A
  76. You plan to collect an SPCollect and log files from the storage system in USM using the Capture
    Diagnostic Wizard. How should this be run?

    A. Engineering mode with password (SIR).
    B. Engineering mode with password (messner).
    C. Log into Unisphere and run “Capture Diagnostic Data”
    D. Log into USM and run “Capture Diagnostic Data”
    A
  77. In a VNX Gateway environment, what is referred to as the "front end"?

    A. NAS Clients
    B. Data Movers
    C. Control Station
    D. SPA host connections
    A
  78. What software is required for a VNX VG10 installation?

    A. VNX OE Express Installation DVD which matches the block OE
    B. VNX OE shipped with the equipment
    C. Latest version of the VIA installation software
    D. VIA installation software shipped with the equipment
    A
  79. How is a storage subsystem connected to a VNX Gateway in a direct-attached environment?

    A. Fibre Channel
    B. Ethernet public LAN
    C. Serial
    D. Ethernet private LAN
    A
  80. On the VNX Gateway platform, which I/O module slot and FC ports are reserved for tape devices?

    A. slot 0, ports 2 and 3
    B. slot 1, ports 2, and 3
    C. slot 0, ports 3 and 4
    D. slot 1, ports 1 and 2
    A
  81. Which condition must be met before starting the Unisphere Storage System Initialization Utility?

    A. No amber lights are blinking on any of the components.
    B. Each Storage Processor power light is steady blue.
    C. The default gateway is configured correctly in each Storage Processor.
    D. The blue lights on the storage processors are blinking at 1 Hz.
    A
  82. Which condition must be met before starting the Unisphere Storage System Initialization Utility?

    A. Computer used for the installation is on the same subnet as the storage system
    B. Computer used for the installation is on the same subnet as the VNX internal network
    C. Amber lights on the power supplies are blinking at 4 Hz
    D. Blue lights on the Storage Processors are blinking at 1 Hz
    A
  83. Which protocols does the Storage System Initialization Wizard use to discover an uninitialized
    VNX?

    A. UDP broadcasts and UDP multicasts
    B. TCP broadcasts and UDP multicasts
    C. TCP broadcasts and TCP multicasts
    D. UDP broadcasts and TCP multicasts
    A
  84. What is the default VNX Unified storage system name?

    A. Array serial number
    B. ImageA and ImageB
    C. Control Station name
    D. Array model number
    A
  85. You are installing multiple VNX arrays, and find that the different arrays share the same serial
    number. What will be the result?

    A. Unisphere may exhibit unpredictable behavior.
    B. Unisphere can still manage each VNX.
    C. The SP Cache of the conflicting VNXs will be disabled.
    D. Unisphere will fail to discover the arrays.
    A