  1. What OO discusses VVO?
    2T-08 Volt Var Optimization (VVO)
  2. When issuing switching steps, is it necessary to instruct a field worker to "lock" a device in the Opened or Closed position?
    • "Manually and electrically operated switches that are provided with locking facilities shall be locked in the appropriate position." SPR 509.11
    • This can be interpreted to mean that you don't have to say "Lock" since it should be locked if possible. It is probably still a good idea to specify to "Lock in Manual / Auto" where necessary.
  3. Which OO explains the general format for all operating orders including numbering structure and subject groups?
    1T-01 BC Hydro Operating Orders - Origin, Administration, Execution
  4. What are Operating Orders?
    They are "BC Hydro management’s standing instructions to operators and field workers regarding electric system operation." 1T-01
  5. Is there a difference between an "OO", a "SOO" and a "DOO"?
    Yes. SOOs (ie 1T) and DOOs (ie 1D) specify the general operation of the BC Hydro integrated electric system and OOs (ie 3T) are a subset of SOOs which specify operation of more specific components of the system. 1T-01
  6. Can an OO or DOO conflict with an SOO?
    No, both OO and DOO are subordinate to SOOs and it is the responsibility of the person(s) approving an OO or DOO to ensure it does not conflict with an SOO. 1T-01
  7. What are JOOs?
    "boundaries and interface operations only." Joint Operating Orders (JOO) are special, jointly signed SOO and OO pertaining to PSSP/WPP operating boundaries and interface operations only. 1T-01
  8. How are OOs grouped?
    They are grouped into Subject Groups represented by numbers 1 to 7. For ex. the 1 in 1T-09 means it is in the "Policy Order" subject group. 1T-01
  9. What are subject groups and how are they represented?
    Subject Groups are used to organize OO according to their content - Represented with Numbers 1 to 7. 1T-01
  10. Regarding OOs, what subject group does 2 represent? Explain that subject group.
    • Technical Orders
    • Cover technical matters without indicating (except as examples) specific systems or plant used by BC Hydro. e.g. operation of gas accumulation and trip features of gas relays, operation of shunt capacitors, descriptions of protection schemes, etc. Note that Orders must pertain to technical operating not to technical maintenance matters. 1T-01
  11. Regarding OOs, what subject group does 3 represent? Explain that subject group.
    • Station Orders
    • Cover operating matters in a specific transmission or distribution substation. Also covers Transmission Voltage Customer facilities and generating station switchyards. 1T-01
  12. Regarding OOs, what subject group does 4 represent? Explain that subject group.
    • Energy Source Orders
    • Cover matters pertaining to meteorology, hydraulic operations, generating station fuels, and energy supplied from sources other than BC Hydro. 1T-01
  13. Regarding OOs, what subject group does 5 represent? Explain that subject group.
    • Transmission and Distribution Circuit Orders
    • Cover operating matters for a specific transmission and distribution circuit(s). Orders related to the transmission and distribution circuit terminal equipment shall appear in station orders. 1T-01
  14. Regarding OOs, what subject group does 6 represent? Explain that subject group.
    • Emergency Orders (general: these OOs don't include procedures for a single station transformer fault or a single line fault, etc.)
    • Outline policies and procedures to be followed during emergencies of a general nature, but not to include procedures for a single station transformer fault or a single line fault, etc. 1T-01
  15. Regarding OOs, what subject group does 7 represent? Explain that subject group.
    • Composite Network Orders
    • Covers orders which in order to describe a specific system requires the naming of a number of stations, lines or combination of each, e.g. GMS/PCN 500 kV system, etc. 1T-01
  16. Regarding OOs, what is the scope of SOO content? System wide matters or procedures which implementation will involve the BC Hydro Control Centre, BC Hydro service providers and other entities. 1T-01
  17. Where are SOOs which contain safety information grouped?
    Between 1T-00 and 1T-30. 1T-01
  18. What is the difference between the numbering structure of SOO / DOO and numbering structure of OO?
    SOO and DOO have 4 digits (XX-XX) and OO have 7 digits (XX-XXX-XX). 1T-01
  19. Where can you find info regarding the T&D Job Lifecycle Safety System?
    1T-02 Series of Operating Orders (T&D Job Lifecycle Safety System)
  20. Who is responsible for determining whether a field worker requires an SPG or Permit such as a LLP? "Workers trained and authorized to PSSP Category 5 or 6 have final responsibility for determining whether they need an SPG or a Permit such as LLP." 1T-02
  21. Who is responsible for determining isolation points on an outage request? Any exceptions?
    The outage requester is responsible except for 1) Dual Radial 2) Network Systems 3) Distribution Isolation for work in stations 4) Expanded zones. 1T-02A
  22. For planned work, when should outages be Submitted by?
    For an 08:00 outage on a given day, planned work should be Submitted AND Approved by 14:00 2 working days in advance. 1T-02A
  23. Regarding outage approval process, what are the main responsibilities of Requesters?
    Thorough adherence to Job Lifecycle Safety Requirements including determining required isolation points that will satisfy LOA requirements. 1T-02B
  24. Regarding outage approval process, what are the main responsiblities of Operations Planning Engineers? Are these OPEs Cat 6 qualified? Ensuring outages' adherance to WECC Reliability Standards. They are not Cat 6 qualified. 1T-02C
  25. Regarding outage approval process, what are the main responsiblities of FVO Area Schedulers? Are Area Schedulers Cat 6 qualified?
    Ensure that proposed / submitted requests are in-line with the Job Lifecycle Safety Requirements. Schedulers have awareness of real-time practical implemenation of work. They are Cat 6 qualified. 1T-02C
  26. Regarding the Job Lifecycle Safety System Approval Stage, what is the difference between a Major Safety Error and a Minor Safety Error?
    Essentially, a Major Safety Error indicates a fundamental lack of understanding or miscommunication about the scope of the work. A Minor Safety Error is either a clerical error or a missing Gas Trip Switch. 1T-02C
  27. For planned work, when should outages be Prepared by?
    The outage must be Approved by 14:00 2 working days in advance and all Preperation must be done by 14:00 1 day in advance. This is so all parties can review the prepared plan before the end of the working day prior to day of the work.
  28. Where can you find information about backfeed from voltage transformers?
    1T-03 Backfeed From Voltage Transformers (CVT and PT)
  29. Prior to issuing an SPG, what must be done to voltage transformers, station service transformers, distribution transformers and metering kits in that zone?
    They must be rendered safe against backfeed. 1T-03
  30. Regarding isolation of voltage transformers, station service transformers, distribution transformers and metering kits; who is responsible for the method by which they are rendered safe against backfeed? What are their options?
    The worker performing the switching is responsible for deciding how the device is rendered safe. The worker has the option to disconnect the cable, open the States Switch, open a low voltage circuit breaker or short circuit the secondary side. 1T-03
  31. Once VTs, SS, distribution transformer or metering kit is rendered safe against backfeed (and therefor tagged); can the tag used for that isolation point be moved or does the field worker have to ask the PIC if they decide to move it?
    "The SPG holder can move the Safety Protection Guarantee Tag from an open States Switch to the disconnected cable without discussing the change with the PIC." 1T-03