LUBE OIL PURIFIER

Home > Preview

The flashcards below were created by user pascual on FreezingBlue Flashcards.


  1. What are the rated capacity of the Fuel Oil Purifier?
    Purifier - 100 gpm
  2. Main engine lube oil purification must be operating (sump to sump) for how long?
    2 hours prior to starting main engine, continuously during main engine operation and for 12 hours after main engine has been shutdown.
  3. L/O outlet temperature from the heater must never exceed what temp?
    195 F
  4. L/O heater outlet temp for SAE 40 weight must be maintained at what temp?
    190 F +/- 5 F
  5. What is the normal speed for the purifier?
    8,500 rpm
  6. What is the purifying rate?
    500 gph
  7. What indicates purifier is up to speed?
    Speed indicator indicates 85 pulsations per 60 sec
  8. What is the purifier manual back pressure valve outlet pressure?
    15-18 psi
  9. Purifier must be placed in what mode prior to SHOOT?
    STBY
  10. How is purifier placed in STBY?
    Place the FLOW FORWARD selector switch to the “STOP/RESET” position
  11. How long should you wait for the purifier to stop?
    4-5 minutes
  12. Purifier should operate how many hours prior to engine start and after engine shutdown?
    2 hours