RJ Systems 2

Card Set Information

Author:
Anonymous
ID:
32804
Filename:
RJ Systems 2
Updated:
2010-09-05 01:58:26
Tags:
fuel electric steering apu press
Folders:

Description:
systems
Show Answers:

Home > Flashcards > Print Preview

The flashcards below were created by user Anonymous on FreezingBlue Flashcards. What would you like to do?


  1. Fuel
    200
    Usable fuel, each wing
    4,760 lbs
  2. Fuel
    700/900
    Usable fuel, each wing
    7,492 lbs
  3. Fuel
    200
    Usable fuel, center tank
    4,998 lbs
  4. Fuel
    700/900
    Usable fuel, center tank
    4,610 lbs
  5. Fuel
    200
    Usable fuel, total
    14,518 lbs
  6. Fuel
    700/900
    Total fuel
    19,594 lbs
  7. Fuel
    All
    max imbalance
    800 lbs
  8. Fuel
    200
    Max imbalance, T/O
    800 lbs
  9. Fuel
    700/900
    Max imbalance, T/O
    300 lbs
  10. Fuel
    200
    Min for GA per wing
    450 lbs (amber)
  11. Fuel
    700/900
    Min for GA per wing
    600 lbs
  12. Fuel
    All
    Min Temp T/O
    +5*C
  13. Elec
    200
    Main Gen
    • to 35,000 ft: 30 kVA
    • >35,000 ft: 25 kVA
  14. Elec
    700/900
    Main Gen
    to 41,000 ft: 40 kVA
  15. Elec
    200
    APU Gen
    to 37,000 ft: 30 kVA
  16. Elec
    700/900
    APU Gen
    to 41,000 ft: 40 kVA
  17. Elec
    200
    Max Cont DC TRU
    100 A
  18. Elec
    700/900
    Max Cont DC TRU
    120 A
  19. Elec
    All
    GND Ops DC ONLY
    5 min
  20. Steering
    200
    Tiller
    70* L/R
  21. Steering
    700/900
    Tiller
    80* L/R
  22. Steering
    200
    Rudder
    5* L/R
  23. Steering
    700/900
    Rudder
    8* L/R
  24. APU
    All
    Max RPM
    107% (red)
  25. APU
    200
    Max Cont EGT
    743*C (red)
  26. APU
    200
    Max EGT Start
    974*C
  27. APU
    700/900
    Max EGT Ground
    789*C
  28. APU
    700/900
    Max EGT Flight
    807*C (red)
  29. APU
    700/900
    Max EGT
    1038*C
  30. APU
    All
    Min Temp Start
    -40*C
  31. APU
    200
    Max Ops Alt
    37,000 ft
  32. APU
    700/900
    Max Ops Alt
    41,000 ft
  33. APU
    200
    Max Start Alt
    30,000 ft
  34. APU
    700/900
    Max Start Alt
    37,000 ft
  35. APU
    200
    Max Alt Bleed use
    15,000 ft
  36. APU
    700/900
    Max Alt Bleed use
    25,000 ft
  37. APU
    200
    Max Alt Eng Start
    13,000 ft
  38. APU
    700/900
    Max Alt Eng Start
    21,000
  39. APU
    200
    Max Gen Load
    30 kVA
  40. APU
    700/900
    Max Gen Load
    40 kVA
  41. APU
    200
    Max speed Door Open with APU not operating
    300 KIAS
  42. APU
    700/900
    Max Speed Door Open with APU not operating
    220 KIAS
  43. APU
    200
    Start AC Batt
    • 2x30 sec ON - 20 min OFF
    • 2x30 sec ON - 40 min OFF
  44. APU
    200
    Start
    • 2x15 sec ON - 20 min OFF
    • 2x15 sec ON - 40 min OFF
  45. APU
    700/900
    Start
    Do not perform more than three start/start attempts in one hour.
  46. A/C
    All
    Max Diff
    8.7 psi
  47. A/C
    All
    Max Neg Diff
    -0.5 psi
  48. A/C
    All
    Taxi, T/O, LND Max
    0.1 psi
  49. A/C
    200
    No man ops
    to -1500 ft
  50. A/C
    200
    Single Pack Ops to
    FL 250
  51. A/C
    700
    Single Pack Ops to
    FL 310
  52. A/C
    900
    Single pack Ops to
    FL 250
  53. A/C
    200
    Pack overheat
    88*C
  54. A/C
    200
    Pack overpressure
    >53 psi
  55. A/C
    All
    Cabin Alt Caution
    >8,500<10,000 ft
  56. A/C
    All
    Cabin Alt Warning
    >10,000 ft
  57. A/C
    200
    CPAM Pax O2
    14,000 +-500 ft
  58. A/C
    700/900
    CPAM PaxO2
    >=14,000 ft
  59. A/C
    All
    CPAM NoSmoFaSB
    10,000 ft
  60. A/C
    200
    EmDepr
    14,250+-750 ft
  61. A/C
    700/900
    Em Depr
    14,500+-500 ft
  62. A/C
    700/900
    EMER DEPRESS Switch
    prohibited above 15,000 ft
  63. A/C
    700/900
    Climb above FL300
    < 1500 FPM

What would you like to do?

Home > Flashcards > Print Preview