  1. Min RPM during engine runup idle check
    975
  2. Min RPM during flight if beyond gliding range of a runway (area idle)
    1400
  3. Min RPM operations with fuel pump off
    1400
  4. Min permissable static RPM (full throttle runup)
    2000
  5. Tachometer normal operating range (rpm)
    700-2800
  6. Max permissable continuous rpm (redline)
    2800
  7. Min RPM drop during magneto check
    25
  8. Max RPM drop during magneto check
    150
  9. Max RPM drop difference between magnetos
    50
  10. Max permissable continuous bhp
    125
  11. Min oil pressure (psi)
    10
  12. Oil pressure normal operating range
    30-60
  13. Max time for oil pressure to reach 10 psi after start (secs)
    30
  14. Max oil pressure for full power operation if OAT < 0C (psi)
    70
  15. Max oil pressure (psi)
    100
  16. Min oil temperature (F)
    75
  17. Max RPM after start until oil temp indication registers
    1000
  18. Oil temperature normal operating range (F)
    170-220
  19. Min oil temperature to begin an area SFL at area idle (F)
    170
  20. Min oil temperature for full power operation if oil pressure normal (F)
    100
  21. Max oil temperature (F)
    240
  22. Min oil quantity (US qts)
    4
  23. Max oil quantity (US qts)
    6
  24. Fuel pressure lower limit red line (psi)
    3.5
  25. Fuel pressure upper limit red line (psi)
    16.5
  26. Max continuous starter operation (secs)
    10
  27. Max cummulative starter op before cooling 3-5 min (sec)
    30
  28. Max time for CHT below 300F in descent (minutes)
    5
  29. Min CHT(F) takeoff & descent
    240
  30. CHT normal operating range (F)
    300-420
  31. CHT caution range (F)
    420-460
  32. Max CHT (F)
    460
  33. Max OAT(C) operation w/ full winterization kit
    0
  34. Max OAT(C) operation w/ partial winterization kit
    12.5